Deskripsi
Double-envelope, single- or double-ended Metal halide lamps
Warnings and Safety
• Use only in totally enclosed luminaire, even during testing (IEC61167, IEC 62035, IEC60598)
• The luminaire must be able to contain hot lamp parts if the lamp ruptures
• Control gear must include end-of-life protection (IEC61167, IEC 62035)
• A lamp breaking is extremely unlikely to have any impact on your health. If a lamp breaks, ventilate the room for 30 minutes and remove the parts, preferably with gloves. Put them in a sealed plastic bag and take it to your local waste facilities for recycling. Do not use a vacuum cleaner.
| General information | |
| Cap base | RX7S [ RX7s] |
| Burning Position | P45 [ Parallel +/-45D or Horizontal(HOR)] |
| Operating and electrical | |
| Power (Rated) (Nom) | 155.0 W |
| Lamp current run-up (max.) | 2.4 A |
| Lamp current (EM) (nom.) | 1.8 A |
| Ignition supply voltage (max.) | 198 V |
| Ignition peak voltage (max.) | 5000 V |
| Ignition supply voltage (min.) | 198 V |
| Ignition peak voltage (min.) | 3500 V |
| Voltage (Max) | 108 V |
| Voltage (Min) | 88 V |
| Voltage (Nom) | 98 V |
| Mechanical and housing | |
| Lamp Finish | Clear |
| Cap-base information | na [ -] |
| Bulb shape | TD |
| Approval and application | |
| Energy Eciency Class | G |
| Mercury (Hg) content (max.) | 12.3 mg |
| Mercury (Hg) content (nom.) | 12.3 mg |
| Energy consumption kWh/1,000 hours | 155 kWh |
| Luminaire Design Requirements | |
| Bulb temperature (max.) | 500 °C |
| Cap base temperature (max.) | 280 °C |